TM 9-2320-285-24-2
4-3.
TORQUE CONVERTER (CONT)
STEP
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY (cont)
NOTE
Don't disassemble stator assembly (21) unless replacement of washers
(34 and 35) or rivets (36) is
14
Stator
a
Rivets (36)
Remove
assembly
(21)
Place stator assembly on drill press,
formed rivet side up. Drill rivets,
removing formed heads, using 3/8
inch drill. Place stator rivet base
under stator assembly (21), as
shown, and top plate on top. Be
sure that holes in stator rivet base
are under rivets. Install capscrew
to hold plates together. Tighten to
60 pounds foot. Place removing,
in- stalling and swaging fixture on
hydraulic press.
Install rivet
removing pin into re- moving,
installing and swaging fixture head
and tighten retainer thumb screw.
Place stator assembly (21) drilled
rivet side up. Press rivets (36) from
stator assembly (21) with rivet
removing pin. Remove removing,
in- stalling and swaging fixture,
capscrew, top plate, and stator rivet
base
b.
Washers (34,
Remove
35, 37 and
38), cam (39)
and stator
(40)
WARNING
Do not strike hardened steel pieces with steel hammer. Metal chips could
cause serious injury to your eyes. Seek medical attention immediately if
you get metal chips in your eyes. Always wear safety goggles when
hammering.
4-8
|