TM 9-2320-285-24-1
2-87.
PRESSURE GAGES MAINTENANCE
c.
FUEL Gage (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Instrument
a. Two nuts (1)Remove
panel,
and lock
underside
washers (2)
b. Bracket (3)
Remove
2
Instrument
Fuel gage (4)
Remove
Lift from instrument panel
panel, top
CLEANING
3
a. Fuel gage (4)
Clean
Wipe with clean, dry cloth
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective
goggles and gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and don't breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you become dizzy while
using cleaning solvent, get fresh air and medical attention immediately. If contact with skin or
clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes
with water and seek medical aid immediately.
b. All other parts
Clean
Use cleaning solvent P-D-680;
dry with clean cloths
INSPECTION
a. Fuel gage (4)
Inspect
Replace if cracked, broken,
or inoperative.
If
electri-
cal contacts dirty or dis-
colored, polish to bright-
ness with fine sandpaper
b. All other parts
Inspect
Replace if cracked, broken,
or threads damaged