TM 9-2320-285-24-1
2-73.
HEATERS MAINTENANCE (CONT)
b.
Defroster Control, Heater Temperature Control, and Fresh Air Control (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION/ADJUSTMENT (cont)
9
e. Nut (18)
Install
(cont)
f. Two clips (12)
Position
Over cable (13) jacket
g. Two screws (11)
Install
Do not tighten
h. Cable (13)
Adjust
Push knob end of cable (13)
in fully while holding
distributor door closed
i. Two screws (11)
Tighten
Secures adjustment
j. Cable (10)
Route and
Push wire end of cable (10)
install
onto fresh air door
bellcrank
k. Clip (9)
Position
Over cable (10) jacket
l. Screw (8)
Install
Do not tighten
m. Cable (10)
Adjust
Push knob end of cable (10)
in fully while holding
fresh air door closed
n. Screw (8)
Tighten
Secures adjustment
o. Heater
Install and
secure
10
Instrument
a. Two locknuts
Install
Slide up to panel (17) and
panel,
(4)
tighten to secure cables
underside
(7 and 10)
b. Nut (3)
Install and
On free end of cable (13)
position
c. Cable (13)
Position
Install free end of cable
(13) from bottom of panel
(17)
d. Tags
Remove
From cables (7, 10, and 13)
11
Instrument
a. Nut (2)
Install and
Secures cable (13)
panel, top
tighten
b. Three knobs (1)
Install
Rotate clockwise
12
Temperature
a. Cable (7)
Route and
Push wire end of cable (7)
valve
install
onto temperature valve
lever
b. Clip (6)
Position
Over cable (7) jacket
c. Screw (5)
Install
Do not tighten
d. Cable (7)
Adjust
Push knob end of cable (7) in
fully while holding temper-
ature valve lever closed
e. Screw (5)
Tighten
Secures adjustment
13
Battery
Battery ground
Connect
box
cable
2-824
|