TM 9-2320-285-24-1
2-33.
HORN SYSTEM MAINTENANCE
b.
Horn Switch (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING
2
a. Horn button (1)
Clean
Wipe with clean, dry cloth
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective
goggles and gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and don't breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you become dizzy while
using cleaning solvent, get fresh air and medical attention immediately. If contact with skin or
clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes
with water and seek medical aid immediately.
Compressed air must not exceed 30 psi. Wear safety glasses when drying parts with
compressed air. Failure to do so could cause serious injury to eyes and possible blindness.
If you hurt your eyes or if a foreign object is blown into your eyes, seek medical attention
immediately.
b. All other metal
Clean
Wipe with clean cloth moist-
parts
ened with cleaning solvent
P-D-680; dry with com-
pressed air or clean cloths
INSPECTION
3
a. Contact assem-
Inspect
Replace if cracked, broken,
bly (12 thru
pins broken or missing, or
14)
otherwise damaged
b. Horn button (1)
Inspect
Replace if cracked or broken
c. Spring seat (2)
Inspect
Replace if cracked, broken,
and retainer
or distorted
(6)
d. Springs (3 and
Inspect
Replace if cracked or
13)
permanently set
e. All other parts
Inspect
Replace if cracked, broken,
or threads damaged
2-373
|