TM 9-2320-285-24-1
2-33.
HORN SYSTEM MAINTENANCE
a.
Horn and Relay (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (cont)
2
Front frame
a. Electrical lead
Disconnect
Unplug from horn (17)
crossmember
(5)
and remove
b. Capscrew (12),
Remove
Support horn and bracket
nut (13),
and
assembly
lock washer
(14)
c. Nut (15) and
Remove
From horn (17)
bracket (16)
CLEANING
3
a. Electrical
Clean
Wipe with clean, dry cloth
leads
(5 thru 7)
and relay (8)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective
goggles and gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and don't breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you become dizzy while
using cleaning solvent, get fresh air and medical attention immediately. If contact with skin or
clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes
with water and seek medical aid immediately.
b. Horn (17)
Clean
Wipe exterior with clean
cloth moistened with
cleaning solvent P-D-680;
dry with clean cloth
c.
All other metal
Clean
Use cleaning solvent P-D-680;
parts
dry with clean cloths
2-368
|