TM 9-2320-285-24-1
2-30. 24V INVERTER MAINTENANCE (CONT)
STEP
LOCATION
ITEM
ACTION
REMARKS
FUSE REPLACEMENT
1
Inverter
a. Two fuse caps
Remove
Push in, turn counterclock-
(7)
(1)
wise, and pull
b. Fuses (2 and 3)
a. Remove
Pull from fuse caps (1)
b. Test
Set multimeter to X1 ohms
range and connect test
leads to ends of fuse.
Replace fuse if multimeter
indicates open circuit
(infinity)
c. Fuses (2 and 3)
Position
Push into fuse caps (1)
d. Fuse caps (1)
Install
Push in and turn clockwise
with fuses
(2 and 3)
REMOVAL
WARNING
Be sure you disconnect battery ground cable before proceeding. Failure to do so could cause death or
serious injury due to electrical shock. If you receive an electrical shock, seek medical aid immediately.
2
Inverter
a. Nine electrical
Tag
Tag leads at inverter (7)
(7)
leads
terminal strip
CAUTION
Do not loosen or remove the brass-colored screws on inverter (7) terminal strip. Remove the chrome-
colored screws (4) only.
b. Nine screws (4)
Remove
c. Nine electrical
Disconnect
From terminal strip
leads
d. Four nuts (5)
Remove
Support inverter (7)
and lock
washers (6)
e. White electri-
a. Tag
cal lead
b. Disconnect
From inverter mounting stud
f. Inverter (7)
Remove
3
Circuit
a. Lights wiring
Tag
Six leads located on same
breakers
harness elec-
side of circuit breakers
(12)
trical leads
(12)
2-308
|