TM 9-2320-285-24-1
2-26. INSTRUMENT PANEL MAINTENANCE (CONT)
e.
Ammeter and 40A Circuit Breaker (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING
4
a. Ammeter (15)
Clean
Wipe with clean, dry cloth
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you
become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with
large amounts of water. If contact with eyes is made, wash eyes with
water and seek medical aid immediately.
b. Circuit breaker
Clean
Wipe with clean cloth moist-
(7) and elec-
ened with P-D-680; dry with
trical leads
clean cloths
(3, 4, 10,
and 11)
c. All other parts
Clean
Use cleaning solvent P-D-680;
dry with clean cloths
INSPECTION
5
a. Ammeter (15)
Inspect
Replace if cracked, broken,
defective, or threads
damaged
b. Circuit breaker
Inspect
Replace if defective, or if
(7)
terminals damaged
c. Electrical
Inspect
Replace if wires cracked,
leads
broken, or frayed, or
terminals missing, damaged,
or corroded
d. All other parts
Inspect
Replace if cracked, broken,
distorted, or threads
damaged
2-271
|