TM 9-2320-285-24-1
2-26. INSTRUMENT PANEL MAINTENANCE (CONT)
a. Switches (cont).
(2) Quick Start Switch (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING (cont)
WARNING
Compressed air must not exceed 30 psi. Wear safety glasses when
drying parts with compressed air. Failure to do so could cause serious
injury to eyes and possible blindness. If you hurt your eyes or if a foreign
object is blown into your eyes, seek medical attention immediately.
b. All other parts
Clean
Use cleaning solvent P-D-680;
dry thoroughly with
compressed air
INSPECTION
3
a. Electrical
Inspect
Replace if insulation frayed
leads
or wire connectors damaged
(2 and 3)
b. Switch (6)
Inspect
Replace if cracked or broken.
Check continuity with ohm-
meter; replace if defective
c. All other parts
Inspect
Replace if cracked, broken,
deteriorated, or threads
damaged
INSTALLATION
4
Instrument
a. Switch (6)
Position
In instrument panel opening
panel
b. Nut (5)
Install and
tighten
c. Rubber boot (4)
Install
Over nut (5)
d. Two electrical
Connect
leads
(2 and 3)
e. Two screws (1)
Install and
Secures leads (2 and 3)
tighten
5
Cab
Instrument panel
Lower and
secure
6
Battery
Battery ground
Connect
box
cable
2-221
|