TM 9-2320-285-24-1
2-26. INSTRUMENT PANEL MAINTENANCE (CONT)
a. Switches (cont).
(2) Quick Start Switch (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
NOTE
Tag and identify all electrical leads before discon-
nection and removal.
1
Instrument
a. Two electrical
Tag
panel
leads (2 and
3)
b. Two screws (1)
Remove
c. Two electrical
Disconnect
leads (2 and
3)
d. Rubber boot (4)
Remove
From nut (5)
e. Nut (5)
Remove
Support switch (6)
f. Switch (6)
Remove
From instrument panel
CLEANING
2
a. Electrical leads Clean
Wipe with clean, dry cloth
(2 and 3),
switch (6),
and rubber
boot (4)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause seri- ous injury. If you
become dizzy while using cleaning solvent, get fresh air and medical
attention immediate- ly. If contact with skin or clothes is made, flush with
large amounts of water. If contact with eyes is made, wash eyes with
water and seek medical aid immediately.