 |  TM 9-2320-285-24-1 2-15. COOLING SYSTEM MAINTENANCE (CONT) a. Radiator (cont). (1) Servicing (cont). STEP LOCATION ITEM ACTION REMARKS DRAINING RADIATOR (cont) 4 Radiator, Radiator cap Loosen, then Turn counterclockwise to top remove first detent. Allow pres- sure to escape before re- moving 5 Radiator, a. 15 gallon Position Under drain cock to drain bottom container coolant into b. Drain cock Open FLUSHING COOLING SYSTEM NOTE Perform steps 3 through 5 above if not already performed. 6 Engine a. 15 gallon Position Under cylinder block drain container cocks b. Cylinder block Open Drain coolant into container drain cocks c. Cylinder block Close When all coolant is drained drain cocks d. Radiator drain Close cock 7 Cab tilt Cab Tilt 45 pump degrees 8 Radiator, a. Inlet and out- Disconnect top rear let hoses and bottom b. Long adapter Connect To inlet and outlet connec- rear hoses tions on radiator c. Flushing gun Connect To adapter hose connected to outlet connection on radi- ator d. Radiator Fill With water e. Radiator cap Install 2-128 | 