TM 9-2320-270-20-3
AIR PRESSURE GAGE - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
REMOVAL CONTINUED
Two adapters (2)
Using 9/16-inch wrench, unscrew and take
7. Two nipples (1)
off.
and (3)
a. Using 9/16-inch wrench, unscrew and
Two nuts (6) and
8. Gage (4) to
take off.
Iockwashers (7)
retainer (5)
b. Get rid of Iockwashers (7).
Take off.
Retainer (5)
9. Gage (4) to
instrument panel (8)
Take out.
Gage (4)
10. Instrument panel (8)
CLEANING
All parts
Clean according to general maintenance
11.
instructions (page 4-1).
lNSPECTION/REPLACEMENT
Inspect according to general maintenance
All parts
12.
instructions (page 4-1).
INSTALLATION
Put in place.
Gage (4)
13. Instrument panel (8)
Retainer (5)
Put on.
14. Gage (4) to instru-
ment panel (8)
Two new Iockwashers
Screw on and tighten using 9/16-inch
15. Retainer (5) to
(7) and nuts (6)
wrench.
gage (4)
Two adapters (2)
a. Wrap nipple threads with teflon tape
16. Two nipples (1)
(page 4-1).
and (3)
b. Screw on and tighten using 9/16-inch
wrench.
Push in and using plastic hammer, seat.
Insert (9)
17. Adapter (3)
a. Lube end lightly with soap and push in
Air line 610 (10)
18.
until seated.
b. Screw on and tighten using 9/16-inch
wrench.
Push in and using plastic hammer, seat.
Insert (11)
19. Adapter (2)
4-1332
|