TM 9-2320-270-20-3
AIR PRESSURE GAGE - CONTINUED
INITIAL SETUP - CONTINUED
Personnel Required
Equipment Condition
One
Instrument panel open (page 4-244).
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Make sure all pressure is drained from air system before disconnecting air lines. Parts
under pressure can, when removed, fly off with great force causing injury to personnel.
1.
Air system
Drain (TM 9-2320-270-10).
2. Gage (1)
Lamp socket (2)
Pull out.
3. Adapter (3)
Air line 41 (4)
Using 9/16-inch wrench, unscrew and
pull out.
4. Air line 41 (4) or
Insert (5)
Using pliers, pull out.
adapter (3)
5. Adapter (6)
Airline 610 (7)
Using 9/16-inch wrench, unscrew and
pull out.
6. Air line 610 (7) or
Insert (8)
Using pliers, pull out.
adapter (6)
4-1331
|