TM9-2320-270-20-3
HEATER COOLANT RETURN ELBOW - CONTINUED
INSTALLATION CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1. Check for leaks (page 4-1).
2. Close right side of hood and install right hood side panel TM 9-2320-270-10).
TASK ENDS HERE
DATA PLATES SECURED WITH BLIND RIVETS
This task covers:
Replacement (page 4-1322)
INITIAL SETUP
Materials/Parts
Tools
Data pIate (as required)
Drill twist, 3/32-inch
Blind rivets, 3/32-inch (as required)
Drill twist, 1/8-inch
Blind rivets, 1/8-inch (as required)
Drill, electric, portable
Hammer, machinist's ball-peen
Personnel Required
Punch, drive pin, 3/32-inch
Punch, drive pin, 1/8-inch
One
Riveter, blind, hand
(as required)
ACTION
REMARKS
ITEM
LOCATION
REPLACEMENT
NOTE
Except as noted, steps in this task apply to all data plates secured with blind rivets.
Noise emissions data plate is shown.
1/8-inch rivets, except for rustproofing data
All data plates secured with blind rivets use
plate, which is secured with 3/32-inch rivets,
a. Using drill and twist, drill off rivet
Four rivets (3)
1. Data plate(1)
heads (4).
to door(2)
b. Using punch and hammer, tap out.
C . Get rid of.
4-1322
|