TM9-2320-270-20-2
AIR DISTRIBUTION MANIFOLD - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
WARNING
Make sure all pressure is drained from air system before disconnecting air lines. Parts
under pressure can, when removed, fly off with great force causing injury to personnel.
NOTE
Tag air lines according to general maintenance instructions (page 4-1).
Drain (TM 9-2320-270-20).
Air system
1.
a. Using cutting pliers, cut and take off.
Tie wrap (4)
2. Air line 488 (1) and
b. Get rid of.
wire (2) to air line
619 (3)
a. Using cutting pliers, cut and take off.
Tie wrap (7)
3. Air line 12 (5) to
b. Get rid of.
elbow (6)
TA240521
4-818
|