TM 9-2320-270-20-2
ACCESSORY PRESSURE PROTECTION VALVE AND MANIFOLD
This task covers:
d. Inspection/Replacement (page 4-756)
a. Removal (page 4-752)
e. Assembly (page 4-756)
b. Disassembly (page 4-755)
f. Installation (page 4-758)
c. Cleaning (page 4-756)
INITIAL SETUP
Materials/Parts
Tools
Lockwasher, air manifold to firewall
Handle, ratchet, 1/2-inch drive
Soap, liquid (item 14, appendix C
Hammer, plastic
Tag, marking (item 18, appendix C)
Pliers, long-nose, round
Tape, teflon (item 22, appendix C)
Socket, deep-well, 1 1/8-inch
1/2-inch drive
Personnel Required
Vise
Wrench, box, 1 1/6-inch
Two
Wrench, open-end, 3/8-inch
Wrench, open-end, 7/16-inch
Equipment Condition
Wrench, open-end, 9/16-inch
Wrench, open-end, 5/8-inch
Instrument panel open (pag 4-244).
Wrench, open-end, 3/4-inch
Left side of hood open (TM 9-2320-270-10).
Wrench, open-end, 13/16-inch
Wrench, pipe, 1/4- to l-inch
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
WARNING
Make sure all pressure is drained from air system before disconnecting air lines. Parts
under pressure can, when removed, fly off with great force causing injury to personnel.
NOTE
Tag air lines and wires according to general maintenance instructions (page 4-1).
Drain (TM 9-2320-270-10).
Air system
1.
4-752
|