TM9-2320-270-20-2
NYLON TUBING - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
REPAIR OF IN-LINE BREAK
WARNING
Make sure all pressure is drained from air system before disconnecting air lines. Parts
under pressure can, when removed, fly off with great force causing injury to personnel.
NOTE
Break in nylon tubing can be repaired by installing a union, provided that very little of
nylon tubing has to be cut so tubing will reach.
If nylon tubing does not reach when damage is cut away, go to steps 70 to 87.
Drain (TM 9-2320-270-10).
Air system
41.
TA240419
4-641
|