TM 9-2320-270-20-1
INTERVEHICULAR WIRING HARNESS RECEPTACLE COVER
This task covers:
a. Removal (page 4-498)
b. Installation (page 4-498)
INITIAL SETUP
Materials/Parts
Tools
Extension, 5-inch, 3/8-inch drive
Lockwasher, receptacle cover and receptacle
Handle, ratchet, 3/8-inch drive
to bracket (four required)
Socket, 7/16-inch, 3/8-inch drive
Wrench, box, 7/16-inch
Personnel Required
One
ACTION
ITEM
LOCATION
REMARKS
REMOVAL
1. Intervehicular
Two nuts (3), lock-
s. Using box wrench, socket, handle, and
wiring harness re-
washers (4), and
extension, unscrew and take out.
screws (5)
ceptacle cover (1)
b. Get rid of lockwashers (4).
to bracket (2)
2. Intervehicular
Two nuts (7), lock-
s. Using box wrench, socket, handle, and
wiring harness
washers (8), and
extension, unscrew and take out.
receptacle cover
screws (9)
b. Get rid of lockwashers (8).
(1) to quick re-
lease valve (6)
3. Bracket (2) and
Take off.
Receptacle cover (1)
receptacle (10)
INSTALLATION
4. Intervehicular
Receptacle cover (1)
Put in place.
wiring harness
receptacle (10)
and bracket (2)
5. Receptacle cover (1)
Two screws (5), new
Screw on but do not tighten.
to bracket (2)
lockwashers (4),
and nuts (3)
4-498
|