TM 9-2320-270-20-1
BULKHEAD CONNECTORS- CONTINUED
ACTION
REMARKS
ITEM
LOCATION
REPAIR
NOTE
Repair is the same for all four bulkhead connectors and plugs. Connectors and plugs
may have male or female inserts. Install back same type insert as shown. Repair of male
plug is shown.
Tag wires according to general maintenance instructions (page 4-1).
Using appropriate size wire removing
Male insert (8)
8. Plug (7)
tool, take out.
Male insert (8)
Using cutting pliers, cut.
9. Wire (9)
Using wire strippers, strip off insulation
Wire (9)
10.
equal to depth of crimping well of new insert.
Using crimping tool, put in crimping well
Wire (9)
11. New male insert (8)
and crimp together.
wire (7)
Push in until positive stop is felt.
Male insert (8) and
12. Plug (7)
Tug lightly on wire to make sure
wire (9)
insert is seated.