Page Title: INSTALLATION - CONTINUED
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-270-20-1
HORNS AND RELAY - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
Left horn (15)
Place in position.
Firewall (14)
30.
Screw in and tighten using socket, handle,
Left horn (15)
Screw (16) and new
31.
lockwasher (17)
and extension.
to firewall (14)
Plug in.
Terminal (18)
GND wire (19)
32.
Plug in.
Wire 168 (12)
Terminal (20)
33.
Firewall (14)
Right horn (21)
Put in place.
34.
Screw in and tighten using socket, handle,
Right horn (21)
Screw (23) and new
35.
Iockwasher (22)
and extension.
to firewall (14)
Plug in.
Terminal (24)
GND wire (25)
36.
Plug in.
Wire 168 (11)
37.
Terminal (26)
NOTE
FOLLOW-ON MAINTENANCE:
1. Connect battery ground cable (page 4-444).
2. Check operation (TM 9-2320-270-10).
3. Close right side of hood (TM 9-2320-270-10).
TASK ENDS HERE
TA240090
4-443