TM 9-2320-270-20-1
PTO
NEUTRAL SAFETY SWITCH
This task covers:
c. Installation (page 4-413)
a. Removal (page 4-412)
b. Cleaning/Inspection (page 4-412)
INITIAL SETUP
Personnel Required
Tools
One
Screwdriver, flat-tip, 3/16-inch
Wrench, box, 7/8-inch
Equipment Condition
Materials/Parts
Power take off in neutral
(TM 9-2320-270-10).
Lockwasher, terminal screw
Packing, safety switch
Tag, marking (item 18, appendix C)
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
NOTE
Tag wires according to general maintenance instructions (page 4-1).
s. Using screwdriver, unscrew and take
Screw (2), lock-
1. Neutral safety
washer (3), and
off.
switch (1)
b. Get rid of Iockwasher (3).
two wires (4)
Using wrench, unscrew and take off.
Neutral safety
2. PTO housing (5)
switch (1)
a. Take off.
Packing (6)
3. Neutral safety
b. Get rid of.
switch (1)
CLEANING AND INSPECTION
Clean and inspect according to general
4.
Neutral safety
maintenance instructions (page 4-1).
switch (1)
4-412
|