TM 9-2320-270-20-1
INTERAXLE DIFFERENTIAL AND TRANSFER CASE WARNING LIGHT SWITCH
This task covers:
c. Installation (page 4-406)
a. Removal (page 4-404)
b. Cleaning/Inspection (page 4-405)
INITIAL SETUP
Personnel Required
Tools
One
Brush, wire
Screwdriver, flat-tip, 1/4-inch
Equipment Condition
Wrench, open-end, 5/8-inch
Wrench, open-end, 1 1/16-inch
Air pressure drained (TM 9-2320-270-10).
Materials/Parts
Lockwasher (two required)
Tape, teflon (item 22, appendix C)
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
WARNING
Make sure all pressure is drained from air system before taking off switch. Parts under
pressure can, when removed, fly off with great force causing injury to personnel.
Using 5/8-inch wrench, unscrew and take
Air line 706(2)
1. Elbow (1)
off.
Using 5/8-inch wrench, unscrew and take
Air line 750 (4)
2. Elbow (3)
off.
Two screws (6),
a. Using screwdriver, unscrew and
3. Switch (5)
take off.
Iockwashers (7),
b. Get rid of Iockwashers (7).
and wires 423 (8)
Using 1 1/16-inch wrench, unscrew and
Switch (5)
4. Tee (9)
take out.
4-404
|