TM 9-2320-270-20-1
TRANSMISSION OIL TEMPERATURE SENDING UNIT
This task covers:
c. Installation (page 4-399)
a. Removal (page 4-398)
b. Cleaning/Inspection (page 4-398)
INITIAL SETUP
Materials/Parts
Tools
Lockwasher, terminal nut to terminal
Extension, 3-inch, 3/8-inch drive
Rags, wiping (item 10, appendix C)
Handle, ratchet, 1/2-inch drive
Solvent, cleaning (item 16, appendix C)
Socket, 7/8-inch, 1/2-inch drive
Tape, teflon (item 22, appendix C)
Wrench, box, 3/8-inch
Universal, 1/2-inch drive
Personnel Required
One
ACTION
REMARKS
ITEM
LOCATION
REMOVAL
a. Using 3/8-inch wrench, unscrew and
Nut (2), Iockwasher
1. Oil temperature
take off.
(3), wire 422 (4),
sending unit (1)
b. Get rid of Iockwasher (3).
and two washers (5
and 6)
Using socket, handle, universal, and
Oil temperature
2. Retarder valve
extension, unscrew and take off.
sending unit (1)
body (7)
CLEANING/lNSPECTION
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors. Do not use near open flame or excessive heat. The flashpoint
is 100F to 138F (38 to 59C). If you become dizzy while using cleaning solvent, get
fresh air immediately and get medical aid. If contact with eyes is made, wash your eyes
with water and get medical aid immediately.
a. Using clean rag dampened with dry-
Oil temperature
3.
cleaning solvent, wipe clean.
sending unit (1)
b. Wipe dry with clean, dry rags.
4-398
|