TM 9-2320-270-20-1
MAGNETIC SWITCH - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1. Connect battery ground cable (page 4-444).
2. Check operation of switch (TM 92320-270-10).
3. Close right side of hood and install right side panel (TM 9--2320-272-10).
TASK ENDS HERE
STARTER RELAY
This task covers:
a. Removal (page 4-238)
b. Installation (page 4-238)
INITIAL SETUP
Personnel Required
Tools
One
Screwdriver, cross-tip, number 3
Screwdriver, fiat-tip, 1/4-inch
Equipment Condition
Materials/Parts
Battery ground cable disconnected
Lockwasher, relay to firewall
(two required)
Tag, marking (item 18, appendix C)
ACTION
ITEM
REMARKS
LOCATION
REMOVAL
WARNING
Make sure battery ground cable is disconnected before doing this task. Failure to dis-
connect ground cable can cause personal injury and damage to electrical system.
NOTE
Tag wires according to general maintenance instructions (page 4-1).
4-236
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |