FUEL RETURN LINES AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
57. Elbow (10) and
Reducer (12)
Screw on and tighten using 7/8-inch
tube (11)
wrench and pipe wrench.
58. Right fuel tank (13)
Reducer (12), elbow
Screw in and tighten using 7/18-inch
(10), and tube (11)
wrench.
59. Elbow (10)
Hose (2)
Screw on and tighten using 3/4-inch
wrench.
NOTE
FOLLOW-ON MAINTENANCE:
1.
Install shutdown solenoid (page 4-422).
2.
Install right side radiator guard (page 4-151).
3.
Check for leaks (page 4-1).
4.
Install right side panel and close right side of hood (TM 9-2320-270-10).
TASK ENDS HERE