TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
74. NEITHER WINCH OPERATES - CONTINUED.
Go to auxiliary transmission (1). Using multimeter set at 30 vdc, put red probe on
Step 8.
terminal for wire no. 154 (2) on auxiliary transmission neutral safety switch (3)
and black probe to good ground.
If meter reads no voltage, put key in OFF position and notify direct
support maintenance.
Using multimeter set at 30 vdc, put red probe on terminal for wire no. 154-A (4)
Step 9.
and black probe to good ground.
If meter reads no voltage, put key in OFF position and replace auxiliary
transmission neutral safety switch (page 4-414).
3-190
|