TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. ENGINE OIL PRESSURE GAGE SHOWS INCORRECT PRESSURE DURING OPERATION (MORE THAN
70 PSI OR LESS THAN 50 PSI) CONTINUED.
Install side panels and hood (TM 9-2320-270-10). Using multimeter set at
Step 6.
30 vdc, put red probe on oil pressure gage terminal (1) and black probe
on panel (2).
a. If meter reads no voltage, close instrument panel (page 4-244) and
notify direct support maintenance.
b. If meter reads voltage, replace oil pressure gage (page 4-259).
c. If engine oil gauge still shows incorrect pressure during operation,
close instrument panel (page 4-244) and notify direct support
maintenance.
TA239619