TM9-2320-270-20-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3.
Start engine (TM 9-2320-270-10) and compare density of exhaust smoke to
chart below.
If smoke is 40 percent density or greater, shut down engine
(TM 9-2320-270-10) and notify direct support maintenance.
Step 4.
Shut down engine (TM 9-2320-270-10). Disconnect fuel return hose (3) from
right fuel tank elbow (4) and put end of hose (3) in container (at least
2-gallon capacity). Start engine (TM 9-2320-270-10) and run at 1,800 rpm
for 1 minute, shut down engine (TM 9-2320-270-10). Check amount of fuel in
container.
If there is less than 0.9 gallons of fuel in container, replace fuel filter
(3) to elbow (4), install right side panel and close right side of hood
(TM 9-2320-270-10).
TA239610
3-21
|