TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. ENGINE CRANKS BUT FAILS TO START (ABOVE 40F) (4.4C) - CONTINUED.
WARNING
Stay clear of fan while engine is being cranked. Failure to do so could result in serious
personal injury or death.
Disconnect fuel inlet hose (1) from fuel pump inlet elbow (2). Connect
Step 5.
vacuum gage to inlet elbow (2). While assistant is cranking engine
(TM 9-2320-270-10), note reading on vacuum gage.
a. If gage shows less than 6 in. (15 cm) Hg of vacuum, replace fuel
pump (page 4-37).
b. If gage shows more than 6 in. (15 cm) Hg of vacuum, remove,
clean, inspect and install fuel lines and fittings (page 4-32),
and purge fuel system (page 4-32).
c. If engine cranks but still fails to start, install right side panel and
close right side of hood (TM 9-2320-270-10) and notify direct
support maintenance.