TRANSMISSION GOVERNOR ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Solvent burns easily. Solvent fumes can explode. Do not smoke or allow open flame nearby when using
solvent. Failure to observe these precautions could cause serious injury or death.
Be sure to wear safety goggles or lenses when using compressed air. Compressed air and particles moved
by compressed air can cause damage to your eyes.
4.
Governor assembly
a.
Clean in drycleaning solvent.
(8) and governor
b.
Dry with compressed air.
cover (1)
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-46).
5.
Governor
a.
Inspect driven gear for scuffed,
assembly (8)
nicked, burred, or broken teeth.
If defect cannot be removed with
soft stone, replace assembly.
b.
Look for bent, restricted, or damaged
flyweights.
TA238493
2-811