TM 9-2320-269-34-1
RELAY BOX - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
5.
Bottom solenoid (1)
Nut (3), lockwasher
a. Using 1/2-inch box-end wrench,
and right
(4), and red
unscrew and take off.
terminal (2)
auxiliary pump
b. Get rid of lockwasher (4).
wire (5)
6
Red auxiliary pump
Two screws (7)
Using 3/16-inch flat-tip screwdriver,
wire (5) and
unscrew but do not take out.
clamp (6)
7.
Relay box (8)
Red auxiliary pump
Pull out.
wire (5)
8.
Bottom solenoid (1)
Nut (10), lockwasher
a. Using 3/8-inch box-end wrench,
and right front
(11), and white
unscrew and take off.
terminal (9)
wires (12) and (13)
b. Get rid of lockwasher (11).
TA238345
2-604
|