CONSOLE TACHOMETER AND OUTRIGGER HYDRAULIC SOLENOID WIRING HARNESS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
57
Relay box (23)
Cable (24) and
Put in position.
wiring harness (25)
58
Top relay (15)
Yellow wire (20)
Solder in place using soldering gun
and bottom rear
and solder.
terminal (19)
59
Bottom front
Two brown wires
Solder in place using soldering gun and
terminal (16)
(17) and (18)
60
Top solenoid (6)
Red throttle control
Screw on, and tighten using 1/2-inch
and right
wire (14), new
box-end wrench.
terminal (11)
lockwasher (13),
and nut (12)
61
Top solenoid (6)
Red wire (10), new
Screw on, and tighten using 1/2-inch
and left
lockwasher (9),
box-end wrench.
terminal (7)
and nut (8)
62
Center solenoid (1)
Black solenoid wire
Screw on, and tighten using 1/2-inch
and right
(5), new washer (4),
box-end wrench.
terminal (2)
and nut (3)
63
Clamp (21)
Two screws (22)
Tighten using 3/16-inch flat-tip
screwdriver.
TA238326