TM 9-2320-269-34-1
CONSOLE TACHOMETER AND OUTRIGGER HYDRAULIC SOLENOID WIRING HARNESS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
48
Center solenoid (1)
Nut (3), lockwasher
a. Using 1/2-inch box-end wrench,
and right
(4), and black
unscrew and take off.
terminal (2)
solenoid wire (5)
b. Get rid of lockwasher (4).
49.
Top solenoid (6)
Nut (8), lockwasher
a. Using 112-inch box-end wrench,
and left
(9), and red
unscrew and take off.
terminal (7)
wire (10)
b. Get rid of lockwasher (9).
50
Top solenoid (6)
Nut (12), lockwasher
a. Using 1/2-inch box-end wrench,
and right
(13), and red
unscrew and take off.
terminal (11)
throttle wire (14)
b. Get rid of lockwasher (13).
51
Top relay (15) and
Two brown
botton front
wires (17) and (18)
terminal (16)
52
Bottom rear
Yellow wire (20)
terminal (19)
53
Clamp (21)
Two screws (22)
Using 3/16-inch flat-tip screwdriver,
unscrew part way.
54
Relay box (23)
Cable (24)
Pull out.
CLEANING
55
Wiring harness (25)
Wipe clean with clean, damp rags.
INSPECTION/REPLACEMENT
NOTE
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
46).
Replace damaged parts as needed.
56
Wiring harness (25)
a
Look for broken terminals.
b.
Look for cracked and burned wires.
c.
Look for frayed and deteriorated
insulation.
2-582
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |