Click here to make tpub.com your Home Page

Page Title: VOLTAGE REGULATOR TESTING - CONTINUED
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-269-34-1
ALTERNATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
VOLTAGE REGULATOR TESTING - CONTINUED
62.
Continued
g.
Adjust carbon pile to get maximum
current output.
h.
If current output is within 10 percent
of 61 amps, the rated output, the alter-
nator components are good.
i.
If current output is not within 10 per-
cent of 61 amps, keep battery loaded
with carbon pile and ground alternator
field.
Ground the field by Inserting screw-
driver In test hole.
NOTE
The tab is located within three-fourths of an inch of the rear face of the frame. Do not force
screwdriver deeper than one inch into the hole.
j.
Operate alternator at moderate rate of
speed and adjust carbon pile to get
maximum output.
k.
If the output is within 10 percent of
61 amps, replace voltage regulator.
NOTE
FOLLOW-ON MAINTENANCE: Install alternator (TM 9-2320-269-20-1).
TASK ENDS HERE
TA238191