TM 9-2320-269-34-1
ALTERNATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY - CONTINUED
38.
Slipring end
Rectifier
Put in position.
frame (12)
bridge (13)
39.
Rectifier
Screw (14) and
Screw in, but do not tighten.
bridge (13)
washer (15)
40.
Terminal (16)
Insulator (17)
Put on.
41.
Nut (18)
Screw on, but do not tighten.
42.
Slipring end
Terminal (16)
Push through hole in frame (12) and
frame (12)
bridge (13).
43.
Terminal (16)
Nut (19) with
Screw on, and tighten using 7116-inch
washer (20)
socket and speeder handle with 1/4-
inch drive.
44.
Rectifier
Screw (14)
Tighten using 1 /4-inch socket and
bridge (13)
speeder handle with 1/4-inch drive.
45.
Slipring end frame
Capacitor with
Put in position.
(12) and rectifier
lead (21)
bridge (13)
46.
Capacitor and
Two screws (22)
Screw in, and tighten using 1/4-inch
lead (21)
socket and speeder handle with 114-inch
drive.
TA238188
2-423
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |