TM 9-2320-269-34-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
HYDRAULIC SYSTEM
27. DERRICK WILL NOT RAISE OR HOLD LOAD
Step 1.
Test main hydraulic pressure (TM 9-2320-269-20-2).
If pressure is low, see LOW OR NO PRESSURE (page 2-44).
Step 2.
Test derrick controls (1).
See step 3 of WINCH CONTROLS DO NOT OPERATE (page 2-40).
Step 3.
Inspect elevation cylinder (2).
Remove elevation cylinder (2) (TM 9-2320-269-20-2), disassemble,
and inspect. Repair or replace as needed, and install (page 2-1591).
28. DERRICK WILL NOT LOWER
See DERRICK WILL NOT RAISE OR HOLD LOAD (above).
29. OUTRIGGERS OPERATE IMPROPERLY - JERKY, WILL NOT HOLD, OR NOT AT ALL
Step 1.
Test main hydraulic pressure (TM 9-2320-269-20).
If pressure is low, see LOW OR NO PRESSURE (page 2-44).
Step 2.
Test outrigger controls (3).
See step 3 of WINCH CONTROLS DO NOT OPERATE (page 2-40).