TM 9-2320-269-34-1
TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
21. MONITOR LIGHT COMES ON AT SPEEDS OVER 15 MPH
Step 1.
Locate faulty signal.
Go to step 1 of MONITOR LIGHT DELAYED - TRUCK NOT MOVING
Step 2.
Inspect brake assembly (2) for binding.
Inspect brake assembly (2) for computer module (1) sending faulty
signal, and repair as needed (TM 9-2320-269-20-1).
Step 3.
Inspect wheel bearing (3) adjustment.
Inspect wheel bearings (3) for computer module (1) sending faulty
signal, and adjust or replace as needed (TM 9-2320-269-20-1).
TA237923
2-35
|