Click here to make tpub.com your Home Page

Page Title: Figure 5-4. Proper position for M crimping blasting cap
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-1300-277
j. Extend arms, point cap out and away from body
(fig. 5-4), and crimp cap at a point 1/8 to 1/4 inch from
WHEN CRIMPING A CAP DO NOT POINT CAP
open end
TOWARD OTHER PERSONNEL OR EXPLOSIVES.
k. Attach fuse igniter as follows:
(1) M2.
(a) Slide fuse retainer over end of fuse
and seat firmly.
(b) Waterproof joint between fuse and
igniter, if necessary, by applying sealing compound.
(2) M60.
(a) Unscrew fuse holder cap two or
three turns.
(b) Press shipping plug into igniter to
release split collet and rotate plug as it is removed.
Figure 5-4. Proper position for M crimping blasting
cap.
(c) Insert end of fuse in place of plug-
until fuse rests against primer base.
Figure 5-5. Deleted.
(d) Tighten cap sufficiently to hold fuse
in place, thus waterproofing joint.
1. Priming with or without priming adapter is as
follows:
(1) With priming adapter (fig. 5-6).
Change 1
5-4

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business