TM 9-1300-275/3
3-2.5 Safety Precautions.
3-2.6.2 Leaks elsewhere can be patched, using
the toxic agent patching kit.
3-2.5.1 Assure that the gasket is in place when
3-2.6.3 If the foregoing operations fail to stop
installing the container lid.
3-2.5.2 Use heavy gloves when installing locking
leaks, replace the container.
rings, to avoid injuring the hands as the locking
3-2.7 Suggested Equipment.
ring snaps into place.
a. Wrenches for locking-ring bolts.
3-2.6 Safing Procedures.
b. Replacement gaskets.
3-2.6.1 If the container leaks at the cover gasket,
c. The toxic agent patching kit.
replace the gasket.