TM 9-1290-232-34&P
SCALE
DIAL
INSTALLATION
TOOLS: 1/8" flat tip screwdriver
PERSONNEL:
One
EQUIPMENT CONDITION: Elevation fire control quadrant in tank or on work bench
FRAME
1
Procedure
Step
Place scale dial (1) on housing (2).
1.
2.
Using screwdriver, install two lockwashers (3) and two screws (4).
3.
Place designation plate (5) on housing (2).
4.
Using screwdriver, install two lockwashers (6) and two screws (7).
NOTE
FOLLOW-ON
MAINTENANCE
D o performance test (Vol I, para 2-2).
END
OF
TASK
II-4-10
|