TM 9-1240-369-34
(4) Remove three screws (92), three lock-
(3) Install new reticle lamp (102) into its slot
washers (93). three washers (94), and video amplifier
and perform steps (1) and (2) in reverse order.
A76A7 (95).
(4) Install  optical  bench  assembly  as
instructed in paragraph 3-12 b).
(5) Install new video amplifier by performing
p. Removal and Installation of R/T Unit Shipping
steps (1) thru (4) in reverse order. Seal screw (90) with
sealant. MIIL-S-22473.
Cover see fig.3-6).
(6) Install  optical  bench  assembly  as
(1) Remove four screws.  (103) and four
instructed in paragraph 3-12 b.
washers (104).
m. Replacement of Fill Valve (see fig. 3-6).
(2) Remove shipping cover (105).
(1) Remove cal, (96) from fill valve stem (97)
(3) Install shipping cover by performing steps
(2) Remove fill valve stem (97) from main
(1) and (2) in reverse order.
housing assembly (106).
(3) Remove fill valve core (98) and strap (99)
3-13. Inspection of Receiver-Transmitter Unit (A76).
from stem (97).
a. Inspect the general condition of all parts. Check
(4) Install new fill valve by performing steps
for wear or other conditions indicating deterioration.
(1) and (3) in reverse order.  Before installing, seal
b. Inspect all circuit cards and all modules for
threads of stem (97) using sealing compound, MIL-S-
corrosion; check all screws for worn threads, check all
11030.
seals for deterioration, and check all machined surfaces
n. Replacement of Relief Valve (see fig. 3-6).
for conditions that may prevent alinement with mating
(1) Remove relief valve (100) from ballistic
parts.  Check all gears, shafts, and bearings for free
(cover assembly (5).
operation.
(2) Install new relief valve (100).  Before
c. Check electrical wiring for chafed or broken
installing, seal threads of relief valve (100) with sealant,
wires and bad solder connections.
MIL-S-22473.
d. Check all optical elements for cleanliness and
o. Replacement of Reticle Lamps (see fig. 3-6).
freedom from surface scratches.
(1) Remove  optical  bench  assembly  as
e. Inspect machined sealing surfaces for scratches.
described in paragraph 3-12 b.
debris or excessive lubricant that may prevent proper
(2) Turn the contacts (101) to one side from
sealing.
their pivotal point and pull faulty reticle lamp (102) out of
its slot.
Section VIII. REPAIR OF CABLE ASSEMBLIES
a. Inspect the general condition of all parts. Check
3-14. General.
for wear or other conditions indicating deterioration.
The system cable assemblies W50 through W54 are
Check connectors for bent pins and presence or o-ring
replaced at organizational level and are to be sent
inside connector around base of pins.
directly to depot for any maintenance. The
only
b. Check electrical wiring for chafed or broken
exception is to cable assembly W50. The terminal lugs
wires and bad solder connections.
may be replaced at GS level maintenance. No special
c. Install cable assembly W50 in hot mock-up and
instructions are required for the replacement of the
perform BIT (para 4-2a).
terminal lugs. Any other repair of interconnecting cable
W50 will be performed at depot.
3-15. Inspection of Cable Assembly W50.
3-25