TM 9-1240-322-34&P
Section 2. MACHINE THREAD PLUG
4-3.
MACHINE THREAD PLUG MAINTENANCE PROCEDURES INDEX
Reference (para)
Task
4-4
Removal
4-5
Installation
MACHINE THREAD PLUG REMOVAL
TOOLS: 3/ 8" flat tip screwdriver
PERSONNEL: One
EQUIPMENT CONDITION: Infinity sight on work bench
FRAME 1
Step
Procedure
1.
Using screwdriver, remove plug (1), spring (2), and plunger (3) from infinity sight
housing (4).
END OF TASK