TM 9-1220-231-34&P
INSPECTION UPON RECEIPT (CONT)
3-2.
FRAME 2
Reference
Step
Procedure
Maintenance Action
Using 1/2" wrench, check four
Tighten. Replace if
1.
...
screws (1) are tight.
missing.
a. TM 9-254
Check index mark on two eccentric
a. Do maintenance
2.
b. Para 4-4,
caps (2) is clear.
procedures.
Frame 2
b. Replace caps if
c. Para 4-5,
damaged.
Frame 5
TM 9-254
Do maintenance
Check two scales (3) on eccentric
3.
procedures, if still not
(4) can be read.
able to read, tell your
supervisor.
...
Tighten. Replace if
Using 15/ 16" wrench, check two
4.
missing.
screws (5) are tight.
...
Tighten. Replace if
Using 15/ 16" wrench, check nut
5.
missing.
(6) is tight.
...
Tighten. Replace if
Using 9/16" wrench, check two
6.
missing.
screws (7) are tight.
Install pins
Check two pins (8) are installed.
7.
GO TO FRAME 3