TM 5-6675-250-34
REPAIR OF AC-DC CONVERTER
r e p l a c i n g defective components.
5-1. General
P e r f o r m resistance checks specified in table 5-1 to
Repair of the ac-dc converter at the direct and
isolate
defective
components.
general support maintenance levels consists of
Points of Measurement
Required Indication
Component
NOTE
Perform resistance checks with an ohmmeter and with power removed from the converter.
Less than 1 ohm
T1-1 to T1-2
Transformer T1
Less than 1 ohm
T1-3 to T1-4
Less than 1 ohm
T1-5 to T1-4
10K ohms 10%
E3 to E4
Resistor R1
Approximately 50 ohms with meter
Meter pos lead to diode pos term;
Diode CR1 and CR2
on Xl scale.
meter neg lead to bus bar.
Capacitor C1
(C1 checked in ripple voltage test,
Less than 1 ohm
Filter FL1
T1-1 to T1-3
Less than 1 ohm
T1-2 to T1-5
a. Removal.
(1) Remove six screws and lift the cover from
the case.
5-1
|