TM 5-6640-214-14
Table 3-1. Preventive Maintenance Checks and Services-Cont
NOTE: Within designated interval, these checks are to be performed in the order listed.
B - Before
A - After
M - Monthly
D - During
W - Weekly
C - Combat Operability Check
Interval
Item to be
Procedures
Equipment will
Item
Inspected
Check for and have repaired
be reported Not
No.
B
D
AWM
C
or adjusted as necessary.
Ready (Red) if:
repairs on defective cyl-
inders, or cylinders with
defective connection
threads. Turn in defective
cylinder to issuing agency
for replacement.
X
Regulators
Check for damage, but do not
use or attempt to repair
defective pressure reg-
ulators. If defective, turn
in to issuing agency for
replacement. Do not
lubricate cylinder valve
or regulator.
X
High Tem-
Lubricate the oil stirrer
perature
motor every 1,000 hours
Viscosim-
of use, applying light
eter cabinet
lubricating oil (Military
Symbol LO)
WARNING
Most cleaning solvents are
hazardous. Avoid prolonged
skin contact and breathing of
vapors, check container
label for warnings.
3-9
|