TM 5-6640-214-14
Table 3-1. Preventive Maintenance Checks and Services
NOTE: Within designated interval, these checks are to be performed in the Order listed.
B - Before
A - After
M - M onthly
D - During
W - Weekly
C - Combat Operability Check
Interval
Item to be
Procedures
Equipment will
Item
Inspected
Check for and have repaired
be reported Not
No.
B
D
AWM
C
or adjusted as necessary.
Ready (Red) if:
X
Pump
Remove top plate and fill
with special vacuum pump
oil until it is slightly above
oil level as indicated in
window on side of pump.
In operation, the oil should
be even with or slightly
above the oil level. If
insufficient oil is used,
a good seal around the
pump vanes will not be
maintained. Too much
oil may back up through
the pump trap into the
vacuum line. Whenever
oil in pump is changed,
pump must run for some
time on a closed system
before lowest pressure
is obtained.
X
Low Tem-
Defrost the ice cube
perature
compartment and lubricate.
Kinematic
the fan motor, check lines
Viscosim-
and fittings.
eter
Cabinet
3-5
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |