TM 5-6640-214-14
Table 3-1. Preventive Maintenance Checks and Services
NOTE: Within designated interval, these checks are to be performed in the Order listed.
B - Before
A - After
M - Monthly
D - During
W - Weekly
C - Combat Operability Check
Interval
Item to be
Procedures
Equipment will
Item
Inspected
Check for and have repaired
be reported Not
No.
B
D
AWM
C
or adjusted as necessary.
Ready (Red) if:
X
Water still
Remove dome cover of
Cabinet
water still after daily use,
(Unit No. 8)
and wipe away accumulated
soft sludge. If sludge has
hardened into a crust, leave
a dilute (about 10%) solu-
tion of acetic acid in the
evaporator overnight.
After this treatment
operate still for about 2
hours to remove all traces
of acid. Make sure that
no distilled water produced
during this period is used.
X
Centrifuge
Use damp cloth to clean
interior and exterior of
centrifuge. Use suitable
solvent or mild soap and
water solution for cleaning
centrifuge tubes. Rinse
tubes with clear water,
and air-dry.
X
Channel
Clean with suitable solvent
Point
or mild soap and water
Apparatus
solution, wipe dry or
air-dry. Periodically
check electrical connec-
tions for tightness.
3-4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |