Table 4-3. Reid Vapor Pressure Apparatus Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
LOSS OF TEMPERATURE CONTROL OF BATH WATER,
Step 1.
Check if stirrer motor is malfunctioning.
Check electrical connections to stirrer motor. Check stirrer
rod (may be bent) and propeller (may be missing). Assure proper
water circulation. Correct applicable defect.
Check for heater element malfunction.
Step 2.
Check electrical connections and assure that there is proper
power supplied to elements. Using electrical circuit tester
assure proper function of elements. Correct applicable defect.
Step 3.
Check thermoregulator for malfunction.
Check thermoregulator. Reset and calibrate as required.
Check location of thermoregulator. Restore to proper location
as required. Check condition of thermoregulator. Replace if
cracked or broken. Reset if bubbles are noted in mercury
columns.