Page Title: SOLVENT FILTERING DISPENSER.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6640-213-14
a.  Clean all parts throughly with a sponge, hot water and a
nonabrasive powdered cleanser.
b.  Rinse all parts thoroughly with hot tap water and then with
distilled water.  Allow all parts to air-dry throughly; do not wipe
dry.  Compressed air may be used to remove traces of moisture.
SOLVENT FILTERING DISPENSER.
3-11.
a,  Cleaning Parts.  Wash the parts of the filter holder in mild
detergent, rinse thoroughly and air-dry to minimize particulate
b.  Aligning Parts.  When the holder is assembled, the cover is
loaded with a flat teflon gasket, a metal support screen, a Millipore
filter, another metal support screen, and another flat teflon gasket.
The cover is fitted to the uptake tube, and the delivery tube is
aligned with the pressure hole on the front of the neoprene bulb.
3-12. WATER DETECTOR KIT, AUTOMOTIVE-AVIATION FUEL.
Never leave the light switch in the ON position if
the light has not come on.  The batteries can be
destroyed or rendered incapable of sustaining a
recharge.
a.  Checking Battery Charge.  Push the light switch down and
outward at the same time and hold for 3 seconds.  Release pressure on
the switch button slowly.  If the light does not come on, repeat the
procedure.  If the light does not operate after the second attempt,
recharge the batteries.
b.  Recharging Battery.  To recharge a battery, remove it from the
instrument and place it in the standard recharger, Model J-330.  The
recharger requires a 110-volt, 60 Hz, power source.
NOTE
Although the battery cannot be overcharged, do not
allow it to remain in the recharger for more than
two weeks without use.
Replacing the Ultraviolet Tube.  To replace the ultraviolet
tube,unmscrew the four roundhead machine screws from the bottom of
the unit to allow removal of the entire bottom half of the assembly.
Pull the metal reflector shield out of its slot to expose the tube.
Remove the tube by grasping both ends at the same time and rotating
the entire tube in either direction, one-quarter turn.  Lift the tube
from its holder.  Install the new tube by reversing the above proced-
ure.  Refer to TM 5-6330-216-12 for complete maintenance procedure on
the Water Detector Kit.