Click here to make tpub.com your Home Page

Page Title: Figure 2-11. Solvent Filtering Dispenser.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6640-213-14
4.  Consult ASTM D-86 petroleum testing refer-
ences for detailed description of test procedure.
(6) Microporous Filtering Disk Holder.
(a)  Description.  Pyrex filter holders are used in the
laboratory to collect particulate material from liquids in accordance
with ASTM D-2276.  One gallon (3.785 liters) of liquid is filtered
using the holder, a laboratory vacuum and a side-arm flask.  The
sample volume actually used must be reported.
(b) Operating Instructions. Complete instructions
for preparation of the test and control membrane filters and field
monitors are described in ASTM D-2276.
(7) Solvent Filtering Dispenser.
(a)
Description.
1.  The solvent filtering dispenser (fig. 2-11)
cleans small volumes by millipore filtration at the point of use,
which eliminates the need for precleaning and the possibility of
contaminating clean liquids.  The dispenser is a combination of a
millipore filter holder and a Guth wash bottle.  Hand pressure forces
solvents through the millipore filter as they are needed.  The
dispenser consists of a pyrex l-liter flask with a neoprene bulb and
stopper, a stainless steel filter holder and support screens with
teflon gaskets and teflon tubing.
Delivery tube
1.
Flask
4.
2.
Filter holder
Uptake tube
5.
Bulb
3.
Pressure release
6.
Solvent Filtering Dispenser.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business