TM 5-6350-275-24&P
Remote unit Enrolled Successfully (This is from the RSMA)
Press Enter
b). LEDs on the RSMA or RDES Top should be 2, 6, 9 illuminated
Step 5. Enter 17 Digit Number
____, ____, ____, ____, _____, _____ (This number is determined locally)
Step 6. First Entry Received
Re-enter 17 Digit Number
____, ____, ____, ____, _____, _____
Step 7. "XXX BACKING UP FILES XXX"
Place diskette containing the "Site" encrypted DES data files into Drive A.
Step 8. Sending Packet ... Packet Received and Acknowledged OK ... Received Block 1-86 File Transfer Complete
Step 9. Compare between current and last file save. Report on number of Bytes that have changed. Press Enter.
Step 10. Main Menu Step 11. Remove diskette and place back into "Site" archived files.
3-248
|